1 Installation The MS350 Wireless Imager is easy to install and use. Please see the following figure showing the steps to perform the installation.
10 Note: DO NOT touch the PCBA inside the imager when replacing the battery. Improper operation may damage the image
100 Italian Pharmacode (Code 32) Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code l
101 Read Disable Enable 00* 01 Max. code length 00-64 00-64 12* Min. code length 00-64 00-64 09* Truncate leading 0-15 00-15 00*
102 Exit Insert group number selection 00* Leading “A” Disable Enable 00* 01 Code-16K Truncate leading/ending: Refer to Truncate leadi
103 Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < >*
104 Exit Insert group number selection 00-44 00-ffH 00-44 00*
105 PDF-417 Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group
106 Exit Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15
107 EAN UCC Composite For the coupon extended code application. Coupon extended code is a supplementary barcode that is printed to the right of the
108 Exit *YAK* UCC / EAN128 emulation Disable Enable 00* 01
109 RSS-14 Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID s
11 Wireless Features The MS350 Wireless model includes an imager and a cradle. When the imager and cradle are linked togeth
110 Exit Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < R4 >* Inse
111 RSS-Limited Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code
112 Exit Code ID setting 00-ffH ASCII code 00-ffH < RL >* Insert group number selection 00-44 00-44 00* UCC/EAN128 emulation Disable
113 RSS-Expanded Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Cod
114 Exit Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < RX >* Insert group number selection 00-44 00-4
115 Micro-PDF Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion grou
116 Exit *XAI* Insert group number selection 00-44 00-44 00* *XAJ* Escape sequence transmit None GLI protocol ECI protocol 00 01 02*
117 String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be tr
118 Exit Option Bar Code Option Alphanumeric Entry Prefix characters setting None 1-22 characters 00* 00-ffH ASCII code Suffix characters se
119 String setting / Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data
12 Auto Update When this feature is enabled, an imager and its linked cradle can automatically ensure they stay in sync with regard to firmware and
120 Exit Option Bar Code Option Alphanumeric Entry Preamble characters setting 1-22 characters “PREAMBLE”* 00-ffH ASCII code Preamble transm
121 String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The imager supports inserting two groups with each
122 5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. 1) Insert data group 1-4 position. Please refer to the speci
123 Option Bar Code Option Alphanumeric Entry Insert G1 characters setting 1-22 characters “GROUP1”* 00-ffH ASCII code Insert G2 characters
124 Exit Insert data group 2 position 00-64 (00: no insertion) 00-64 00* Insert data group 3 position 00-64 (00: no insertion) 00-64 00* Ins
125 String setting / Transmission (Others) Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before C
126 Exit Code ID position Before code data After code data 00* 01 Code ID transmission Disable Proprietary ID AIM ID 00* 01 02 Code length trans
127 Test Chart (Bar code samples marked with symbol “*” are enabled initially.) CODABAR-PARA CODE-11 PARA CODE-128 PARA * CODE-39 PARA * CODE-
128 PDF-417 * STANDRAD-25 PARA CODE-16K EAN-8 PARA * INDUSTRIAL-25 PARA UPCE PARA * 87549
129 INTERLEAVED-25 PARA * MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA * UK/PLESSEY PARA RSS Micro-PDF *
13 ? Enable firmware auto update only – Allows only firmware updating. ? Disable auto update – No automatic updates will be performed.
130 ASCII Code Table Note: For keyboard wedge only. L H 0 1 0 1 0 Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F
131 Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current barcode reading configuration o
132 Exit Query present cradle firmware version Program Firmware version list If you wish to display the cradle a
133 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D
14 Deep Sleep Mode The WIRELESS imager can be placed into Deep Sleep Mode after this programmed duration (since the units ’ last scanning activity
15 Handcuff Mode (Leash Alarm) When enabled, the Leash Alarm will force the imager to sound an alarm for a preprogrammed length of time to notify i
16 Wireless Connectivity The MS350 can be linked to any Bluetooth (BT) enabled device which can accept such a connection with other devices. To imp
17 Wireless Connectivity (continued) User is also allowed to set any four- to six-character PIN code assigned to the target Bluetooth device using
18 Inquiry Beep Control When the cradle is not linked to an imager, the Radio LED will blink amber and the cradle will beep. This beep can be disab
19 ? Inquiry beep every 50 seconds ? Inquiry beep every 60 seconds ? Inquiry beep every 70 seconds *$%-5AJ05%%**$%-5AJ06%%**$%-5AJ0
2 How To Scan 1. The imager must be pointed at slight angle to the barcode so that the light reflected off the barcode can be seen by the imager. D
20 Cradle Beep Loudness Control The beep loudness of cradle can be defined with the following levels. ? Cradle beep off ? Level 1 ? Lev
21 ? Level 6 ? Level 7 *$%-5AK06%%**$%-5AK07%%*
22 Additional Features Here list three additional features of MS350 wireless imager for the convenience of use to users. ? Download firmware from
23 Default setting For each barcode shown as below: Code Type Read Enable Checksum Verification Enable Checksum TransmissionEnable Code ID UPC-
24 Specification Unitech MS350 Specification Model MS350 Operational Light Source 630 nm Visible Red LED Optical System 2048 pixel CCD (Charge-
25 Depth-head 44 mm Weight Less than 200g (with a battery) Case material ABS (over molded at contact points) Cushion material Double injection C
26 Current – Sleep (Imager) 2 mA Light Level Up to 45000 Lux Shock (Imager) 1.5m drop onto concrete Shock (Cradle) 90cm drop onto concrete Conta
27 Indications of MS350 Imager: Status Green LED Red LED Orange LED Beeper Link established Blink once A special beep Loss link (handcuff mode
28 Cradle: Status Green LED Red LED Orange LED Beeper Inquiry Blink Beeps once a second Connecting Blink Link established ON Ha
29 Programming the MS350 To program the MS350, you must scan a series of programming barcode in the correct order. Fold out the back cover of this ma
3 Troubleshooting If the imager can not operate properly, the following checks should be performed: 1. The cradle uses an external power supply an
30 Option Bar Code Option Alphanumeric Entry Interface selection Keyboard Wedge RS-232 Wand emulation USB Keyboard/RS-232 Auto d
31 Exit Interface Selection This cradle comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, and USB interface. In
32 Exit Keyboard wedge As a keyboard interface, the cradle supports most of the popular PCs and IBM terminals. The installation of the wedge is a fa
33 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need
34 Entry Keyboard layout USA Belgium Danish France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American Japanese 00* 01 02 03 0
35 Exit only) Alt+Keypad 02 Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, imager can get Caps Lock status. Power-on s
36 Exit Option Bar Code Option Alphanumeric Entry Caps lock Caps lock”ON” Caps lock”OFF” 00 01* Power-on simulation Disable Enable 00*
37
38 RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII
39 Exit Option Bar Code Option Alphanumeric Entry Flow control None RTS/CTS Xon/Xoff ACK/NAK RTS/CTS bracket mode 00* 01 02 03 04 Inter-chara
4 3. Verify the interface cable is securely connected to the cradle. 4. Check that the barcodes are of sufficient quality to be recogniz
40 Exit Option Bar Code Option Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02
41
42 Pin Assignments 10-pin AS Series 10-pin RJ-45 Connector Pin RS-232 Keyboard 1 I/F I/F 2 NA NC 3 TXD NC 4 NC CLK / PC 5
43 Keyboard Wedge PS/2 Connector (To Host Side): Pin Mini-DIN 6P Male Mini-DIN 6P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4
44 Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of imager stops scanning when there
45 Exit Option Bar Code Option Alphanumeric Entry Scanning mode Good-read off Momentary Alternate Timeout off Continue Test only 00 01* 02 0
46 Scan Global min./max. code length: These are to define the min/ max readable code length of all symbologies. Code length less than min. code leng
47 Exit Option Bar Code Option Alphanumeric Entry Global min. code length 00-99 00-99 04* Global max. code length 00-99 00-99 99* Inverte
48 Indication Power on alert: After power-on the cradle it will generate an alert signal to indicate a successful self -test. LED indication: Aft
49 Exit Option Bar Code Option Alphanumeric Entry Power on alert Disable Enable 00 01* LED indication Disable Enable 00 01* Beeper indicati
5 Wireless Connection Linking the imager with the cradle Follow these instructions to link the two devices: 1. Connect power to the cradle. The ra
50 UPCA Format Leading Zero Data Digits (11 Digits) Check Digit Read: Enable or disable the read function. Check -sum transmission: By setting Enabl
51 Exit Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01* Check-sum transmission Disable Enable 00 01* Truncate leading
52 UPCA Insertion group number selection: The imager offers max. two insertion grou
53 Exit Option Bar Code Option Alphanumeric Entry Insert group number selection 00-44 00-44 00* Supplement digits None 2 digits 5 digits
55 UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check -sum transmission: By setting Enable, checks sum will be transmitted.
56 Exit Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < E >*
57 UPCE Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Supplement digits: Format Leading Zero Data Dig
58 Exit Supplement digits None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 00* 01 02 03 04 05 06 07 Truncation/
59 EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate
6 Unlinking There are three ways to unlink an imager from a cradle: Force imager to disconnect and sleep 1. Scan the “Force imager to di
60 Exit Truncate ending 0-15 00-15 00*
61 EAN-13 Code ID setting: Refer to page 51 Insertion group number selection of UPCA. Insertion group number selection: Refer to Insertion group sel
62 Exit Supplement digits None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 00* 01 02 03 04 05 06 07 ISBN/ISSN co
63 EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate lead
64 Exit Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH, 00-ffH < FF >* Insert group number selection 00-44 00-4
65 EAN-8 Supplement digits: Format Data Digits (7 Digits) Check Digits Supplement Digits 2 or 5 or UCC/EAN 128 Truncation / Expansion: Refer to Trun
66 Exit 02 Expansion Disable Enable 00* 01
67 Code 39 Read: Format Start “? ” Data Digits ( Variable) Checksum (Optional) End “? ” Check -sum verification: The checksum of Code-39 is optio
68 Exit Check-sum verification Disable Enable 00* 01 Check-sum transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. c
69 Code 39 Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanc
7 4. Push the “Reset” button on the bottom of cradle – If the cradle is linked with an imager and in range, pushing the “Reset” button (for about 2
70 Exit Format Standard Full ASCII 00* 01 Append Disable Enable 00* 01 Start/end transmission Disable Enable 00* 01
71 Interleaved 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Check -sum verification: The checksum is made as the sum module 10 of
72 Exit Check-sum transmission Disable Enable 00* 01 Max. code leading 00-64 00-64 00* Min. code leading 00-64 00-64 00* Truncate leading
73 Industrial 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Tru
74 Exit Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < i >* Insert group nu
75 Matrix 2 of 5 Eur Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 10 of t
76 Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading
77 Exit Insert group number selection 00* Codabar Read: Format Checksum Verification: The checksum is made as the sum module 16 of the numerica
78 Exit Checksum Verification Disable Enable 00* 01 Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. co
79 Codabar Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Start/End type: The Codabar has four p
8 Battery Charging The imager contains a 1000mAh Lithium-Ion rechargeable battery. A full charged battery will provide up to 15,000 scans over a 12
80 Exit Start/End transmission Disable Enable 00 01* Code-128 Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification:
81 Exit Checksum Transmission Disable Enable 00* 01
82 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Cod
83 Exit Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < # >* Insert g
84 Exit Code-128 ISBT enable: This feature is commonly used in a blood bank for identification. ISBT concatenation timeout: This feature is to setup
85 Exit Code-93 Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The checksum is made as the s
86 Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Co
87 Exit Code ID setting 00-ffH ASCII code 00-ffH < & >* Insert group number selection 00-44 00-44 00*
88 Code-11 Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The checksum is presented as the s
89 Exit Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading
9 How to Change the Battery In case the contained battery inside the imager needs to be replaced, please follow the procedures below:
90 MSI/plessey Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The MSI/Plessey has one or two
91 Exit 03 Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate lead
92 UK/plessey Read: Format Data Digits (Variable) Checksum1+2 (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum di
93 Exit Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading
94 Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the
95 Exit Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-
96 Standard 2 of 5 Read: Format Data Digits (Variable) Checksum1 (Optional) Check -sum verification: The checksum is made as the sum module 10 of
97 Exit *JAC* Check-sum transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate lea
98 China Post Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncat
99 Exit Min. code length 11* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code
Comments to this Manuals