AutoLF
Use the [ ] key to toggle between ON or OFF, then hit ENTER to make the select
ion.
When AutoLF is set to ON, the HT580 will append a LF (10 hex) character to the input
data block.
Mode
Use the [ ] key to toggle between BLOCK and CHAR, then h
it ENTER to make the
selection.
Line/Page
Use the [ ] key to toggle among LINE, PAGE and BOTH, then hit ENTER to make the
selection.
FormCaching < FORM >
FormCaching is a built-in application generator on the HT580 which allows users to
create a data entry application from the device by specifying eld prompt, eld length,
data type, input method, delimiter, etc, without writing a program and loading it to the
HT580. Entry data can be processed in batch mode or 2 real time modes.
Batch mode Stores your data (according to your settings) into “FORM.DAT”. The
user can use the communication program to get this le from the
device to a PC.
On line None Directly sends the record data via RS232/USB or Bluetooth (according
to your port settings) after recording your data. Data will still be stored
into “FORM.DAT.”
On line Multi Follows Unitech’s Multi-protocol. Data will be stored in the system area
and wait for a remote polling command.
To provide a convenient way to distribute Formcaching settings, users are able to import
and export FormCaching settings from one HT580 to another.