MS146 Manual
Bar Code Symbologies, continued
Code 93
Enabled toggles the ability for the keyboard/scanner to read
Code 93 on or off. Default is “Yes”.
Code ID is a user-definable identification letter for Code 93,
which is referred to in the “Use Code ID” function (see page 11).
Default is letter “L”.
Minimum Length defines the minimal length the user will accept
for a valid bar code. Default is “1”.
Maximum Length defines the maximum length the user will
accept for a valid bar code. Default is “48”.
MSI / Plessey Code
Enabled toggles the ability for the keyboard/scanner to read MSI
/ Plessey Code on or off. Default is “Yes”.
MSI Code ID is a user-definable identification letter for MSI
Code, which is referred to in the “Use Code ID” function (see
page 11). Default is letter “O”.
Plessey Code ID is the same as MSI Code ID (above), but
instead applicable to Plessey Code. Default is the letter “P”.
Send Check Digit toggles whether or not to send a check digit.
Default is “No Send”.
Check Digit Formula defines the formula to calculate the check
digit. Options are: “Double Module 10”, Module 11 Plus 10”, and
“Single Module 10”. Default is “Double Module 10”.
Minimum Length defines the minimal length the user will accept
for a valid bar code. Default is “1”.
Maximum Length defines the maximum length the user will
accept for a valid bar code. Default is “16”.