23
Chapter 2 Using the Hardware
When in setting mode, there are 3 options – SETTING, IMPORT and EXPORT as shown
in menu below.
EXPORT Saves FormCaching’s conguration as “FORM.SET”.
IMPORT Changes FormCaching conguration from the “FORM.SET” le.
SETTING Congures FormCaching‘s operation ow.
When SETTING is selected, the HT580 will rst ask the user to specify data elds in
four categories, including eld prompt, data length, data type and device type. After
dening all of the data eld options, use the ESC key to end the setup. Below
is a table
describing all of the FormCaching Setting options.
FormCaching Specication
DATA FIELD DEFINITION: maximum eld number= 8
Category Range Descr
iption
FIELD PROMPT Max.16 characters set eld prompting
MIN/MAX
F
ield LENGTH
1-48 Set minimum and maximum
eld length
Field type 1.NUMERIC
2.ALPHANUM
Numeric data (0~9) or
alphanumer
ic data
(20H~FCH)
DEVICE TYPE 1.KEY ONLY
2.SCAN ONLY
3.BOTH
Input by keyboard only, bar
code scann
ing only or both
1. SETTING
2. IMPORT
3. EXPORT